Publication:
Analyzing the environmental effects of conventional and condensing combi boilers using natural gas

cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.departmentc27a3f89-18ff-442e-984d-632876718f47
cris.virtualsource.orcidc27a3f89-18ff-442e-984d-632876718f47
dc.contributor.affiliationGazi Üniversitesi, Teknoloji Fakültesi, Enerji Sistemleri Mühendisliği, Teknikokullar, 06500, Ankara, Türkiye Türk Hava Kurumu Üniversitesi, Makine Mühendisliği, Bölümü, 06790, Ankara, Türkiye
dc.contributor.authorHalil İbrahim VARIYENLI Ataollah KHANLARI
dc.date.accessioned2024-07-11T10:49:34Z
dc.date.available2024-07-11T10:49:34Z
dc.date.issued2020
dc.description.abstractGenerally, space heating and hot water providing are done by combi boilers. Different types of combi boilers are available. In therecent years condensing combi boilers have been introduced that have high energy efficiency in comparison with conventionaltypes. In the condensing type combi boilers, an additional heat exchanger is utilized to recover energy form flue gas. In this studythe effects of combi boiler type on pollutant gas emissions have been experimentally analyzed. In this regard three different combiboiler including conventional, condensing and full condensing type combi boilers have been selected in the experiments. Inaddition, the experiments have been done in different temperatures to investigate the temperature effect. The obtained resultsshowed that in all temperatures using condensing and full condensing combi boilers reduced CO2, NO and NOx gas emissionsconsiderably. Also, by analyzing combi boilers emissions in different working temperatures, it can be said that in low temperaturesCO2 emission reduction in condensing combi is higher than its reduction in high temperatures in comparison with conventionalone.
dc.description.doi10.2339/politeknik.592313
dc.description.endpage1284
dc.description.issue4
dc.description.startpage1277
dc.description.volume23
dc.identifier.eissn2147-9429
dc.identifier.issn1302-0900
dc.identifier.urihttps://acikarsiv.thk.edu.tr/handle/123456789/2035
dc.language.isoeng
dc.relation.journalPoliteknik Dergisi
dc.titleAnalyzing the environmental effects of conventional and condensing combi boilers using natural gas