Publication:
Numerical and experimental analysis of parallel-pass forced convection solar air heating wall with different plenum and absorber configurations

cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.departmentdb60d807-ceb7-4fd6-b393-8ff48234192b
cris.virtualsource.orciddb60d807-ceb7-4fd6-b393-8ff48234192b
dc.contributor.affiliationTurk Hava Kurumu University; Turkish Aeronautical Association; Gazi University; Erzurum Technical University; Mehmet Akif Ersoy University; Gazi University; Duzce University; Gazi University
dc.contributor.authorKhanlari, Ataollah; Sozen, Adnan; Afshari, Faraz; Tuncer, Azim Dogus; Agbulut, Umit; Yilmaz, Zeynep Aytac
dc.date.accessioned2024-06-25T11:46:08Z
dc.date.available2024-06-25T11:46:08Z
dc.date.issued2022
dc.description.abstractPurpose Over the recent years, solar energy has received outstanding attention from researchers. Solar energy applications and related large-scale projects are increasing to meet growing global energy demand as an economical, non-polluting and renewable energy source. The purpose of this study is investigating different plenum and absorber configurations of solar air heating wall (SAHW) experimentally and numerically. Design/methodology/approach In this study, various configurations of SAHW have been numerically simulated to determine the most effective design. According to the simulation results, two SAHWs with various plenum thicknesses have been fabricated and tested at different conditions. Findings Numerical simulation results indicated that parallel-flow SAHWs exhibited better performance in comparison with other placements of absorber plate. Regarding to the experimentally attained results, the highest thermal efficiency was reached to 80.51%. Also, the average deviation between experimentally and numerically obtained outlet temperature is 5.5%. Originality/value Considering the obtained results in the present study, designed SAHW has admissible efficiency to be used in various industrial and residential applications such as; air preheating, space heating and drying.
dc.description.doi10.1108/HFF-03-2021-0160
dc.description.endpage1001
dc.description.issue3
dc.description.pages24
dc.description.researchareasThermodynamics; Mathematics; Mechanics
dc.description.startpage978
dc.description.urihttp://dx.doi.org/10.1108/HFF-03-2021-0160
dc.description.volume32
dc.description.woscategoryThermodynamics; Mathematics, Interdisciplinary Applications; Mechanics
dc.identifier.issn0961-5539
dc.identifier.urihttps://acikarsiv.thk.edu.tr/handle/123456789/1377
dc.language.isoEnglish
dc.publisherEMERALD GROUP PUBLISHING LTD
dc.relation.journalINTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW
dc.subjectThermal performance; Plenum; Absorber placement; Solar air heating wall; Solar thermal
dc.subjectTHERMAL PERFORMANCE; COLLECTOR; SYSTEM; DRYER; HEATER; ENERGY; EXERGY; PLATE; ENHANCEMENT; ALUMINUM
dc.titleNumerical and experimental analysis of parallel-pass forced convection solar air heating wall with different plenum and absorber configurations
dc.typeArticle
dspace.entity.typePublication

Files